Servoventilator Chirana Aura V represents modern technology for artificial lung ventilation designed for the full range of patient (adult, children, newborn and prematurity) With tidal volume from 2 ml to 2000 ml and respiratory frequency 1-180 / min. A comprehensive range of ventilation modes includes some unique ventilation mode as HFM-CPAP (high frequency modulated CPAP), nCPAP (nasal CPAP), PMLV (programmed multi-Level ventilation) or CFvS (continuous flow support), which are also in basic configuration.

The device can be equipped with an external compressor fixed on the chassis of device, as a backup system in case of failure pressurized air source, module for complex gas analysis (Mainstream or Sidestream) and nebulizer (pneumatic or ultrasonic)

Ventilation modes:

  • CMV - continuous mandatory /mechanical/ ventilation 

  • SCMV - synchronized continuous mechanical ventilation 

  • PC V - pressure controlled ventilation 

  • SPCV  - synchronized pressure controlled ventilation

  • SIMV(V)+PS – volume controlled artificial inspirium with pressure supportSIMV(P)+PS – pressure controlled artificial inspirium with pressure support

  • PS – pressure support

  • APRV (BIPAP) – airway pressure release ventilation

  • 2-Level – two level ventilation (Bilevel, BiPAP, DuoPAP)

  • 2-Level+PS – ventilation at two pressure levels with pressure support at both pressure levels

  • CPAP – continuous positive airway pressure

  • nCPAP - continuous pressure in the respiratory tract at spontaneously ventiled patient, without the weight limit with the nasal application

  • PMLV® - programmed multi level ventilation

  • HFM CPAP – high frequency modulated CPAP for application at childrem below 5 kg of weight

  • APMV® (MVs) – automatic proportional minute volume – self-adaptive regulative system based on maintaining the selected minute ventilation MV 

  • CFvS® - continuous flow support

  • SIGH – Sigh (deep breath)

  • PS-VG - pressure support volume guaranted or called PS-CMV

  • PC-VG- presssure control volume guarranted

  • SIMV-VG - synchronized intermittent mandatory ventilation volume guarranted

  • BIPAP (2LV)-VG - two level ventilation volume guarranted

  • PMLV®-VG - programmed multi level ventilation volume guarranted

Technical parameters

 

Power supply:

  • O2, AIR supply pressure 2,8-6 bar

  • max. inspiration flow 240 l.min-1  O2=120 l/min  AIR=120 l/min

  • electirc power supply    TN-S 110 - 240 V, 50/60 Hz

  • battery  12 V/ 8 Ah Pb

  • running time on own resource at default parameters 4 hours

 

Ventilation parameters: 

  • Tidal volume: 2 – 2 000 ml  

  • breathing frequency: 1 – 180/ min.  

  • minute ventilation: 0,1 – 35 l/min.

  • ratio Ti:Te, %: 10 – 90% ( 1:299 - 9:1)  

  • inspiration pause:  0 - 75% 

  • concentration O2 21 - 100%

  • PEEP:  0 - 5 kPa

  • Sigh:  OFF , OFF,10 to 100 settable by  10

  • Inspiration flow: 240 l/min

  • Trigger sensitivity:  1 - 20 l/min  flow 

                               0,1 - 1,5 kPa  pressure                                                                

  •  bias-flow:  1 - 30 l.min-1, OFF

  • display: 15“ touchscreen

 

Monitoring parameters:

  • pressure – paw,

  • tidal volume Vt,

  • minute ventilation MV,

  • minimal pressure pmin = PEEP,

  • medium pressure,

  • concentration FiO2 

  • concentration inspirium/expirium CO2MIN and CO2MAX 

  • frequency f,

  • T/M – activity of patient breathing

  • Metabolics of patient

 

The graphs on the display:

  • pressure curve,

  • P/V curve            

  • flow curve,

  • Q/V curve            

  • volumetric curve,

  • P/V curve,

  • Q/V curve

  • CO2 curve

 

Monitoring the mechanical properties of the lung:

  • Time constant period of inspirium and expirium,

  • peak alveolar pressure,

  • alveolar pressure of end-tidal PEEP,

  • alveolar pressure

  • Auto PEEP,

  • static lung compliance,

  • dynamic lung compliance.

  • inspiration resistance of airways and  ventilation system

Safety:

• There is implemented a three-level system of alarms

• Alarm system works through sound and light signals to the display and remembering causes

• sophisticated system for extreme situations, allowing when you enter the patient's weight, to make a quick start appliance in ventilation modes CMV

• Auto-start ventilation system

• Integrated electronic fan provides increased protection against hypoxic mixture

• Secure Electronic Control FiO 2

• When oxygen supply disruption, the device makes the air ventilation from a source of compressed air or external compressor

• on-line monitoring of the mechanical properties of the lung